Z purlin sizes, weights and load tables

Select a Z purlin by load

Design based on ASD to AISI: allowable working (unfactored) loads, for 2 or more bays and roof slopes up to 3:10

Sectionkg/mRoof weight (kg/m²)Allowable working load (kN/m²)Total UDL (kN)UDL for span/180 (kN)Uplift 0 rods (kN)1 rod2 rods3 rods
Z 182153.572.980.846.065.284.024.026.06–
Z 182184.283.571.087.746.35.165.167.26–
Z 182204.763.971.218.77.025.765.767.98–
Z 182255.924.931.5110.868.587.27.29.84–
Z 202153.923.2717.27.144.744.747.74–
Z 202184.73.921.248.948.525.945.949.54–
Z 202205.234.361.4310.269.426.846.8410.5–
Z 202256.535.441.8313.1411.648.768.7612.84–
Z 232154.533.781.218.710.985.826.9610.38–
Z 232185.444.531.5511.1613.147.448.5213.02–
Z 232206.045.031.7612.6614.528.349.4815.12–
Z 232257.556.292.3416.8617.9411.2211.5219.32–
Z 252154.763.971.299.313.266.127.3810.92–
Z 252185.714.761.712.2415.98.168.9414.28–
Z 252206.345.281.9514.0417.529.249.8416.5–
Z 252257.936.612.618.7221.7212.4812.4820.76–

Z purlin sizes and section properties

35 sizes · d, t, a, b, c in mm

Sectionkg/md (mm)t (mm)a (mm)b (mm)c (mm)Ix defl (cm⁴)Sx(t) (cm³)Sx(b) (cm³)Sxe(t) (cm³)Sxe(b) (cm³)Rx (cm)Iy (cm⁴)Sy (cm³)Ry (cm)
Z 122152.921221.555501788.514.814.2313.09913.9224.86429.924.612.828
Z 142153.211421.5555020128.918.4817.8317.20317.65.58533.655.012.854
Z 142183.851421.8555020153.321.9921.2121.9921.215.57139.95.962.842
Z 142204.291422555020169.324.2923.4324.2923.435.56143.996.582.834
Z 142255.361422.5555020208.629.9228.8629.9228.865.53753.918.092.815
Z 172153.451721.555501519422.9522.1920.0421.496.61727.584.332.495
Z 172184.141721.855501523127.3226.4225.6926.086.60232.685.142.483
Z 172204.61722555015255.330.229.228.8228.926.59236.015.672.476
Z 172255.751722.555501531537.2536.0237.2536.026.56744.086.972.457
Z 182153.571821.5555016223.724.9824.1922.1123.496.96528.744.462.497
Z 182184.281821.8555016266.429.7528.8129.6928.496.9534.075.32.485
Z 182204.761822555016294.532.8931.8531.7431.626.93937.555.842.478
Z 182255.951822.5555016363.540.639.340.639.36.91445.967.182.459
Z 202153.922021.5605516301.730.3229.4426.2928.417.72135.865.162.662
Z 202184.72021.8605516359.636.1335.0832.534.27.70542.546.132.65
Z 202205.232022605516397.739.9638.837.4938.257.69546.916.772.643
Z 202256.532022.5605516491.449.3847.9448.0547.677.6757.518.332.624
Z 232154.532321.5706517462.740.439.3831.9737.548.955.226.893.075
Z 232185.442321.8706517551.948.1946.9841.445.218.88465.618.23.063
Z 232206.042322706517610.853.3451.9945.8850.058.87472.429.063.056
Z 232257.552322.5706517755.966.0164.3462.0763.458.84989.0211.173.037
Z 252154.762521.5706516558.944.943.8234.0641.659.56353.416.712.956
Z 252185.712521.8706516666.853.5852.2946.1250.249.54763.447.992.945
Z 252206.342522706516738.159.3157.8750.9455.579.53770.028.832.937
Z 252257.932522.5706516913.973.4371.6668.6370.479.51186.0610.882.918
Z 262155.182621.5807220672.852.350.4538.1547.8510.06981.498.893.504
Z 262186.222621.8807220803.262.4360.2351.157.5310.05496.9310.593.493
Z 262206.912622807220889.369.1366.6858.8764.0510.044107.0711.713.485
Z 262258.632622.58072201101.985.6682.6275.8980.2210.019131.8914.463.466
Z 302186.853021.88580161159.177.5575.9954.0371.1711.483106.2411.253.477
Z 302207.6130228580161283.885.984.1764.8479.3311.473117.3712.443.469
Z 302259.523022.58580161592.2106.53104.3887.6198.911.447144.6415.373.45
Z 342208.76342210092201939.869103.96874.61774.94103.96813.1193.6812.944.138
Z 3422510.873422.510092202405.8135.769110.126111.507130.89513.67239.09616.434.12
Z 3423012.95342310092202862.35164.412145.933144.158158.10713.041283.34521.3894.102

Z purlin weight and selection

Roof weight per square metre is the purlin weight divided by the purlin spacing, before laps, sleeves and sag rods. To design the purlin from roof loads and wind, use our purlin design calculator. For the weight of a full material list, add Z purlins in our steel weight calculator. For purlin types, spacing, laps and sag rods, see our guide to purlins in steel structures. See also our warehouse and PEB steel structure design service.

What sizes of Z purlins are available in the UAE?

Z purlins are cold-formed from galvanized steel to ASTM A653M SQ Grade 50 (fy = 345 N/mm²) with G90 zinc coating, in depths from 122 mm to 342 mm and thicknesses of 1.5, 1.8, 2.0, 2.5 and 3.0 mm, weighing 2.92 to 12.95 kg/m.

How do you read a Z purlin designation?

The code gives the depth and the thickness: Z 20220 is about 202 mm deep and 2.0 mm thick, and Z 23218 is about 232 mm deep and 1.8 mm thick.

How do you select a Z purlin for a roof?

Choose the lap system (butt, sleeve or overlap), the span between frames and the purlin spacing, then pick the lightest purlin whose allowable load at that spacing is at least the working (unfactored) load on the roof. Check uplift with the number of anti-sag rods as well.

How do you estimate the weight of purlins per square metre of roof?

Divide the purlin weight in kg/m by the purlin spacing in metres. A 4.76 kg/m purlin at 1.5 m spacing weighs about 3.2 kg per square metre of roof, before laps and sag rods.